Tankless Flow Calculator

A tankless heater makes hot water as you use it, so its size comes down to flow and temperature rise. Choose the showers and fixtures that run at the same time to see what a unit has to deliver.

Pick your place and we set the incoming water temperature from its winter weather.

Showers running at once
At the same time as the showers

What runs at the same time

A tank stores hot water. A tankless unit makes it as you go, so it is sized in gallons per minute, not gallons. Add up what realistically runs together. We use 2.5 gallons per minute for a showerhead, which is the federal limit, about 1.8 for a faucet and about 2 for a dishwasher or washer. Two showers at once already means 5.

How cold the water comes in

We assume a hot water setting of 120°F, the level the US Department of Energy recommends. Colder January weather means colder water entering the heater, so the calculator uses three bands. A January low of 40°F or higher assumes 65°F incoming water. From 25°F to 40°F it assumes 52°F. Under 25°F it assumes 42°F, a 78°F rise. Detroit lands in that last band.

How the size is worked out

The heat a unit has to deliver each hour is the flow in gallons per minute, times the rise in degrees, times 500. That figure comes from the weight of a gallon of water. We round it and place it in one of our own planning bands, based on that delivered heat. Up to 90,000 BTU per hour is a small unit. Up to 150,000 is a standard whole-house unit. Up to 190,000 is a large unit. Above that, two units are linked together.

A tankless unit trades flow for rise. The same unit gives more gallons per minute at a small rise than at a big one, which is why every tankless rating is stated at a rise.

Gas and electric limits

Gas units go up to about 199,000 BTU per hour of input, and two can be linked. Electric units top out near 36 kW, about 123,000 BTU per hour, and they need a very large electrical service. The result shows how many gallons per minute each one delivers at your rise. A plumber or an electrician checks the gas line, the electrical service and the venting before any unit is chosen.

Common questions

What size tankless heater suits a family of four?

Plan on two showers running together, about 5 gallons per minute. At a 78°F rise that needs roughly 195,000 BTU per hour, a bit above one large gas unit, so the result points to the two-unit band. Enter your own fixtures in the calculator to see yours.

Can one tankless unit run two winter showers at once?

Not quite. Two showers draw about 5 gallons per minute, while a large gas unit delivers about 4.9 at a 78°F rise. For two showers at full flow, look at two linked units. A single unit suits one shower at a time.

What is temperature rise on a tankless heater?

It is the number of degrees the unit has to add. Water that arrives at 42°F and leaves at 120°F has a 78°F rise. Each flow rating is tied to a stated rise, and the unit gives fewer gallons per minute as the incoming water gets colder.

Will an electric tankless heater cover a whole house?

Not on its own. A 36 kW electric unit, near the top of the range, gives about 3.1 gallons per minute at a 78°F rise. That serves one shower, and it also calls for a very large electrical service that an electrician has to confirm.

Does a tankless water heater need a bigger gas line?

Often. A 199,000 BTU per hour unit draws several times what a tank heater does, and the existing gas line and venting may not be sized for it. A plumber checks both first.

Data: fixture flow rates from the federal showerhead limit and typical faucet and appliance flows, the 120°F setpoint recommended by the US Department of Energy, and incoming water bands set from Daymet winter data 2015 to 2024 for each place.